Please let us know if you would like an estimate or receipt.
We will do our best to accommodate your needs.
| ■Product Name |
|
【With Calibration Certificate】
SOKIA
Reflectorless Total Station
SET4110RS Shift Type
■Calibration Date: April 2022
※Not used since calibration
|
| ■Included Accessories |
・Instruction manual
・Calibration certificate
・Internal battery
・Charger
・Silicone cloth
・Tool set (screwdriver, adjustment pin, lens brush)
・Plumb bob
・Lens hood
・Storage case
※Everything shown in the photos is included.
Please note that items not shown in the photos are not included.
●Batteries that need replacement, and parts or consumables requiring replacement
Are not covered by the product's initial defect or operation warranty. Please arrange these yourself if needed. Thank you for your understanding.
|
|
The SET4110RS is an advanced model with reflectorless capability added to the SET4110!!
The functions and operation of the SET3110R/SET4110RS are nearly identical to those of the SET2110/SET3110/SET4110. A high-performance model that holds its own against the SET3030.
Measuring range: 1.0m–1600m (when using a single-prism AP reflective prism) ・ Minimum angle display: 10″/5″ ・ Angular accuracy: 5″ ・ Weight: 5.5kg (with battery)
Memory: approx. 3,000 points; maximum 24 jobs ・ Built-in programs (missing line measurement, REM measurement, offset measurement, two-point target measurement, 3D coordinate measurement,
stakeout measurement, resection, automatic direction angle setting, repetition measurement)
Easy-to-use control panel (Japanese kana can also be entered for coordinates)
Large display shows graphics as well as alphanumeric characters and kana.
Large amounts of information, including measurements, point numbers/names, 3D coordinates, and selected modes, can be
viewed all at once.
●Base Type: Shift type
●Certification: Geospatial Information Authority of Japan Class 3
●Angular Accuracy: 5"
●Angle Measurement Method: Incremental angle measurement
●Distance Measurement Accuracy: (2mm+2ppm×D) m.s.e. ※SET4110RS is the shift type
|
| ■Condition |
■Operation has been checked!!
To ensure we deliver a good product, we performed the following cleaning prior to sale.
Areas cleaned
・Exterior cleaning
・Interior cleaning
However, this is a used item and has minor scratches from use. The contrast on one of the LCD screens is low, making it somewhat difficult to see. Please understand that this is an older item.
※The item will be delivered in the condition shown in the photos. Please purchase only if you are satisfied with its condition.
|
|
▼Telescope
Overall length: 165mm
Effective aperture: 45mm (EDM: 50mm)
Magnification: 30x
Image: Erect
Resolving power: 3″
Field of view: 1°30′
Minimum focusing distance: 1.0m
Focusing mechanism: 2-stage fine/coarse adjustment
Reticle illumination: Bright/dim (selectable)
▼Angle Measurement Section
Measurement method: Incremental method with 0 index (absolute origin)
Minimum display: 5″/10″
Accuracy: 5″
Angle measurement interval: Continuous measurement at intervals of 0.5 seconds or less
Automatic tilt compensation mechanism
Compensates for vertical and horizontal angles / vertical angle only / no compensation (selectable)
Type: Liquid (2-axis)
Minimum display: Follows the selected minimum angle display setting
Range: ±3′
Angle measurement modes
Horizontal angle: Right/left rotation/hold/repetition (selectable)
Vertical angle: Zenith 0°/horizontal 0°/horizontal 0° ±90° (selectable)
▼Distance Measurement Section
Measurement method: Coaxial near-infrared laser modulation, phase-difference measurement method
Measurement range
White paper: 2–85m
Reflective sheet RS90N: 2–500m
Minimum display
Fine measurement: 1mm
Rapid measurement: 1mm
Maximum slope distance display: 9999.999m
Accuracy
Fine measurement: White paper ±(5+3ppm×D)mm
Reflective sheet ±(3+3ppm×D)mm
Prism ±(5+3ppm×D)mm
Rapid measurement: White paper ±(7+5ppm×D)mm
Reflective sheet ±(7+5ppm×D)mm
Prism ±(7+5ppm×D)mm
Measurement time: Fine measurement: 3.7 seconds for the first measurement, then every 2.0 seconds (up to 10 times)
Rapid measurement: 3.1 seconds for the first measurement, then every 1.2 seconds (up to 20 times)
Light source: Laser diode
Wavelength: 830nm
Distance measurement return signal check: Display/audio on/off (selectable)
Atmospheric correction, temperature input range: -30–60° (1°C increments)
Pressure input range: 500–1400 hPa (1 hPa increments)
Prism constant correction value: -99–99mm
▼Power Supply
Battery: BDC35
▼Other Specifications
Bubble tube sensitivity: Horizontal bubble tube: 30″/2mm
Circular bubble: 10′/2mm
Optical plummet image: Erect
Magnification: 3x
Minimum focusing distance: 0.5m
Horizontal/telescope fine-motion controls: 2-stage fine/coarse adjustment
Operating temperature range: -20–50°C
Instrument height: 236mm
Dimensions: 177 (W) × 165 (D) × 345 (H) mm
Weight: Main unit 5.7kg
※Specifications are provided for reference only, based on information from the manufacturer's website.
Some details may be incorrect. Please contact us if you notice any errors, and we will correct them. Please treat this information as a general guide only.
For details, please contact the manufacturer.
|
|
Ships from Kyoto
■Shipping (prepaid shipping only)
Flat rate: ¥3,200 nationwide
The same shipping fee applies to Hokkaido, Okinawa, and remote islands.
※All items we ship are covered by shipping insurance.
Please contact us if the item is damaged in transit.
If the damaged part can be repaired, we will arrange a repair.
Returns are not accepted. Thank you for your understanding.
|
Please let us know if you would like an estimate or receipt.
We will do our best to accommodate your needs.
●We can issue a set of three documents: estimate, invoice, and delivery note.
Please provide the necessary details for issuance (billing address, shipping address, date for the seal, etc.).
※If you need these documents, please contact us before purchasing.
|